Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.364
Filter
1.
Environ Health Perspect ; 132(5): 55001, 2024 May.
Article in English | MEDLINE | ID: mdl-38728219

ABSTRACT

BACKGROUND: In response to the COVID-19 pandemic, new evidence-based strategies have emerged for reducing transmission of respiratory infections through management of indoor air. OBJECTIVES: This paper reviews critical advances that could reduce the burden of disease from inhaled pathogens and describes challenges in their implementation. DISCUSSION: Proven strategies include assuring sufficient ventilation, air cleaning by filtration, and air disinfection by germicidal ultraviolet (UV) light. Layered intervention strategies are needed to maximize risk reduction. Case studies demonstrate how to implement these tools while also revealing barriers to implementation. Future needs include standards designed with infection resilience and equity in mind, buildings optimized for infection resilience among other drivers, new approaches and technologies to improve ventilation, scientific consensus on the amount of ventilation needed to achieve a desired level of risk, methods for evaluating new air-cleaning technologies, studies of their long-term health effects, workforce training on ventilation systems, easier access to federal funds, demonstration projects in schools, and communication with the public about the importance of indoor air quality and actions people can take to improve it. https://doi.org/10.1289/EHP13878.


Subject(s)
Air Pollution, Indoor , COVID-19 , SARS-CoV-2 , Ventilation , COVID-19/transmission , COVID-19/prevention & control , Humans , Air Pollution, Indoor/prevention & control , Ventilation/methods , Air Microbiology , Disinfection/methods , Respiratory Tract Infections/prevention & control , Respiratory Tract Infections/transmission
2.
PeerJ ; 12: e17268, 2024.
Article in English | MEDLINE | ID: mdl-38708351

ABSTRACT

Objective: To study the efficacy of PADTM Plus-based photoactivated disinfection (PAD) for treating denture stomatitis (DS) in diabetic rats by establishing a diabetic rat DS model. Methods: The diabetic rat DS model was developed by randomly selecting 2-month-old male Sprague-Dawley rats and dividing them into four groups. The palate and denture surfaces of rats in the PAD groups were incubated with 1 mg/mL toluidine blue O for 1 min each, followed by a 1-min exposure to 750-mW light-emitting diode light. The PAD-1 group received one radiation treatment, and the PAD-2 group received three radiation treatments over 5 days with a 1-day interval. The nystatin (NYS) group received treatment for 5 days with a suspension of NYS of 100,000 IU. The infection group did not receive any treatment. In each group, assessments included an inflammation score of the palate, tests for fungal load, histological evaluation, and immunohistochemical detection of interleukin-17 (IL-17) and tumor necrosis factor (TNF-α) conducted 1 and 7 days following the conclusion of treatment. Results: One day after treatment, the fungal load on the palate and dentures, as well as the mean optical density values of IL-17 and TNF-α, were found to be greater in the infection group than in the other three treatment groups (P < 0.05). On the 7th day after treatment, these values were significantly higher in the infection group than in the PAD-2 and NYS groups (P < 0.05). Importantly, there were no differences between the infection and PAD-1 groups nor between the PAD-2 and NYS groups (P > 0.05). Conclusions: PAD effectively reduced the fungal load and the expressions of IL-17 and TNF-α in the palate and denture of diabetic DS rats. The efficacy of multiple-light treatments was superior to that of single-light treatments and similar to that of NYS.


Subject(s)
Diabetes Mellitus, Experimental , Disinfection , Rats, Sprague-Dawley , Stomatitis, Denture , Animals , Male , Rats , Stomatitis, Denture/microbiology , Stomatitis, Denture/radiotherapy , Stomatitis, Denture/drug therapy , Disinfection/methods , Tolonium Chloride/pharmacology , Tolonium Chloride/therapeutic use , Tumor Necrosis Factor-alpha/metabolism , Interleukin-17/metabolism , Disease Models, Animal
3.
J Med Virol ; 96(5): e29655, 2024 May.
Article in English | MEDLINE | ID: mdl-38727091

ABSTRACT

Viruses can spread through contaminated aerosols and contaminated surface materials, and effective disinfection techniques are essential for virus inactivation. Nonthermal plasma-generated reactive oxygen and nitrogen species can effectively inactivate the coronavirus. We aim to interpret the coronavirus inactivation level and mechanism of surface interaction with materials with and without dielectric barrier discharge (DBD) plasma treatment. Nonthermal plasma, particularly surface-type DBD plasma, can inactivate human coronavirus 229E (HCoV-229E) on porous (paper, wood, mask) and nonporous (plastic, stainless steel, glass, Cu) materials. Virus inactivation was analyzed using a 50% tissue culture infectivity dose (TCID50) using cell line, flow cytometry, and immunofluorescence. Surfaces contaminated with HCoV-229E were treated at different time intervals (0-5 h) with and without plasma exposure (natural decay in ambient air conditions). HCoV-229E persistence conformed to the following order: plastic > cover glass > stainless steel > mask > wood > paper > Cu with and without plasma exposure. HCoV-229E was more stable in plastic, cover glass, and stainless steel in 5 h, and the viable virus titer gradually decreased from its initial log10 order of 6.892 to 1.72, 1.53, and 1.32 TCID50/mL, respectively, under plasma exposure. No virus was observed in Cu after treatment for 5 h. The use of airflow, ambient nitrogen, and argon did not promote virus inactivation. Flow cytometry and immunofluorescence analysis demonstrated a low expression level of spike protein (fluorescence intensity) during plasma treatment and in E and M genes expression compared with the virus control.


Subject(s)
Coronavirus 229E, Human , Plasma Gases , Virus Inactivation , Humans , Coronavirus 229E, Human/drug effects , Coronavirus 229E, Human/physiology , Virus Inactivation/drug effects , Plasma Gases/pharmacology , Cell Line , Porosity , Disinfection/methods , Stainless Steel
4.
Sci Adv ; 10(18): eadl5067, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701201

ABSTRACT

Airborne pathogens retain prolonged infectious activity once attached to the indoor environment, posing a pervasive threat to public health. Conventional air filters suffer from ineffective inactivation of the physics-separated microorganisms, and the chemical-based antimicrobial materials face challenges of poor stability/efficiency and inefficient viral inactivation. We, therefore, developed a rapid, reliable antimicrobial method against the attached indoor bacteria/viruses using a large-scale tunneling charge-motivated disinfection device fabricated by directly dispersing monolayer graphene on insulators. Free charges can be stably immobilized under the monolayer graphene through the tunneling effect. The stored charges can motivate continuous electron loss of attached microorganisms for accelerated disinfection, overcoming the diffusion limitation of chemical disinfectants. Complete (>99.99%) and broad-spectrum disinfection was achieved <1 min of attachment to the scaled-up device (25 square centimeters), reliably for 72 hours at high temperature (60°C) and humidity (90%). This method can be readily applied to high-touch surfaces in indoor environments for pathogen control.


Subject(s)
Disinfection , Electronics , Graphite , Disinfection/methods , Electronics/methods , Graphite/chemistry , Microbial Viability , Bacteria
5.
J Hazard Mater ; 471: 134340, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38640670

ABSTRACT

While the effectiveness of Poly-Aluminum Chloride (PAC) coagulation for pollutant removal has been documented across various wastewater scenarios, its specific application in hospital wastewater (HWW) treatment to remove conventional pollutants and hazardous genetic pollutants has not been studied. The research compared three hospital wastewater treatment plants (HWTPs) to address a knowledge gap, including the PAC coagulation-sodium hypochlorite disinfection process (PAC-HWTP), the biological contact oxidation-precipitation-sodium hypochlorite process (BCO-HWTP), and a system using outdated equipment with PAC coagulation (ODE-PAC-HWTP). Effluent compliance with national discharge standards is assessed, with BCO-HWTP meeting standards for direct or indirect discharge into natural aquatic environments. ODE-PAC-HWTP exceeds pretreatment standards for COD and BOD5 concentrations. PAC-HWTP effluent largely adheres to national pretreatment standards, enabling release into municipal sewers for further treatment. Metagenomic analysis reveals that PAC-HWTP exhibits higher removal efficiencies for antibiotic resistance genes, metal resistance genes, mobile genetic elements, and pathogens compared to BCO-HWTP and ODE-PAC-HWTP, achieving average removal rates of 45.13%, 57.54%, 80.61%, and 72.17%, respectively. These results suggests that when discharging treated HWW into municipal sewers for further processing, the use of PAC coagulation process is more feasible and cost-effective compared to BCO technologies. The analysis emphasizes the urgent need to upgrade outdated equipment HWTPs.


Subject(s)
Hospitals , Oxidation-Reduction , Sodium Hypochlorite , Wastewater , Water Pollutants, Chemical , Wastewater/chemistry , Sodium Hypochlorite/chemistry , Water Pollutants, Chemical/chemistry , Waste Disposal, Fluid/methods , Disinfection/methods , Water Purification/methods , Polymers/chemistry , Aluminum Hydroxide
6.
J Hazard Mater ; 471: 134365, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38669926

ABSTRACT

The disinfection of fabrics is crucial in preventing the spread of infectious diseases caused by pathogenic microorganisms to maintain public health. A previous study proved that plasma-activated nebulized mist (PANM) could effectively inactivate microorganisms both in aerosol and attached to the surface. In this study, the PANM driven by different plasma gases were employed to inactivate microorganisms on diverse fabrics. The PANM could efficiently inactivate a variety of microorganisms, including bacteria, fungi, and viruses, contaminating different fabrics, and even across covering layers of different fabrics. The mites residing on the cotton fabrics both uncovered and covered with various types of fabrics were also effectively inactivated by the PANM. After 30 times repeated treatments of the PANM, notable changes were observed in the color of several fabrics while the structural integrity and mechanical strength of the fabrics were unaffected and maintained similarly to the untreated fabrics with slight changes in elemental composition. Additionally, only trace amounts of nitrate remained in the fabrics after the PANM treatment. Therefore, the PANM treatment supplied an efficient, broad-spectrum, and environmentally friendly strategy for industrial and household disinfection of fabrics.


Subject(s)
Plasma Gases , Textiles , Plasma Gases/pharmacology , Animals , Disinfection/methods , Bacteria/drug effects , Fungi/drug effects , Nebulizers and Vaporizers , Viruses/drug effects
7.
J Hazard Mater ; 470: 134254, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38615644

ABSTRACT

The existence of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) has been a global public environment and health issue. Due to the different cell structures, gram-positive/negative ARB exhibit various inactivation mechanisms in water disinfection. In this study, a gram-negative ARB Escherichia coli DH5α (E. coli DH5α) was used as a horizontal gene transfer (HGT) donor, while a gram-positive ARB Bacillus as a recipient. To develop an efficient and engineering applicable method in water disinfection, ARB and ARGs removal efficiency of Fe(VI) coupled peroxydisulfate (PDS) or peroxymonosulfate (PMS) was compared, wherein hydroxylamine (HA) was added as a reducing agent. The results indicated that Fe(VI)/PMS/HA showed higher disinfection efficiency than Fe(VI)/PDS/HA. When the concentration of each Fe(VI), PMS, HA was 0.48 mM, 5.15 log E. coli DH5α and 3.57 log Bacillus lost cultivability, while the proportion of recovered cells was 0.0017 % and 0.0566 %, respectively, and HGT was blocked. Intracellular tetA was reduced by 2.49 log. Fe(IV) and/or Fe(V) were proved to be the decisive reactive species. Due to the superiority of low cost as well as high efficiency and practicality, Fe(VI)/PMS/HA has significant application potential in ARB, ARGs removal and HGT inhibition, offering a new insight for wastewater treatment.


Subject(s)
Gene Transfer, Horizontal , Iron , Peroxides , Peroxides/chemistry , Iron/chemistry , Water Purification/methods , Escherichia coli/drug effects , Escherichia coli/genetics , Drug Resistance, Bacterial/genetics , Disinfection/methods , Sulfates/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Bacillus/genetics , Bacillus/drug effects , Bacillus/metabolism
8.
BMC Microbiol ; 24(1): 143, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38664628

ABSTRACT

BACKGROUND: Broiler chickens are frequently colonized with Extended-Spectrum Beta-Lactamase- (ESBL-) and plasmid mediated AmpC Beta-Lactamase- (pAmpC-) producing Enterobacterales, and we are confronted with the potential spread of these resistant bacteria in the food chain, in the environment, and to humans. Research focused on identifying of transmission routes and investigating potential intervention measures against ESBL- and pAmpC- producing bacteria in the broiler production chain. However, few data are available on the effects of cleaning and disinfection (C&D) procedures in broiler stables on ESBL- and pAmpC- producing bacteria. RESULTS: We systematically investigated five broiler stables before and after C&D and identified potential ESBL- and pAmpC- colonization sites after C&D in the broiler stables, including the anteroom and the nearby surrounding environment of the broiler stables. Phenotypically resistant E. coli isolates grown on MacConkey agar with cefotaxime were further analyzed for their beta-lactam resistance genes and phylogenetic groups, as well as the relation of isolates from the investigated stables before and after C&D by whole genome sequencing. Survival of ESBL- and pAmpC- producing E. coli is highly likely at sites where C&D was not performed or where insufficient cleaning was performed prior to disinfection. For the first time, we showed highly related ESBL-/pAmpC- producing E. coli isolates detected before and after C&D in four of five broiler stables examined with cgMLST. Survival of resistant isolates in investigated broiler stables as well as transmission of resistant isolates from broiler stables to the anteroom and surrounding environment and between broiler farms was shown. In addition, enterococci (frequently utilized to detect fecal contamination and for C&D control) can be used as an indicator bacterium for the detection of ESBL-/pAmpC- E. coli after C&D. CONCLUSION: We conclude that C&D can reduce ESBL-/pAmpC- producing E. coli in conventional broiler stables, but complete ESBL- and pAmpC- elimination does not seem to be possible in practice as several factors influence the C&D outcome (e.g. broiler stable condition, ESBL-/pAmpC- status prior to C&D, C&D procedures used, and biosecurity measures on the farm). A multifactorial approach, combining various hygiene- and management measures, is needed to reduce ESBL-/pAmpC- E. coli in broiler farms.


Subject(s)
Bacterial Proteins , Chickens , Disinfection , Escherichia coli , Farms , beta-Lactamases , Animals , beta-Lactamases/genetics , beta-Lactamases/metabolism , Chickens/microbiology , Escherichia coli/genetics , Escherichia coli/drug effects , Escherichia coli/isolation & purification , Disinfection/methods , Bacterial Proteins/genetics , Bacterial Proteins/metabolism , Escherichia coli Infections/veterinary , Escherichia coli Infections/microbiology , Escherichia coli Infections/transmission , Poultry Diseases/microbiology , Poultry Diseases/prevention & control , Anti-Bacterial Agents/pharmacology , Phylogeny , Plasmids/genetics , Multilocus Sequence Typing , Whole Genome Sequencing
9.
J Water Health ; 22(4): 735-745, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38678426

ABSTRACT

Swimming is a widely practiced exercise in modern society, where there is a heightened interest in health. The exceptional benefits of swimming are well-known, yet the issue of water quality management inevitably arises due to its nature as an aquatic exercise. Several studies reported that chlorine disinfectants commonly used in swimming pool water disinfection could degrade into toxic disinfection by-products (DBPs) and suggested that the DBPs might induce respiratory disorders, including asthma. Conversely, there were also reports that the DBPs had no significant effects on respiratory conditions. In this study, we investigated the influence of swimming exercise and DBPs on asthma. The decomposition products had little effect on the number of T cells in various immune organs. However, swimming exercise was found to increase the cell count in proportion to the exercise duration. Nevertheless, there were no significant changes in other immune cells and the secretion of asthma-related cytokines. These findings indicate that the effects of swimming pool DBPs on respiratory conditions during swimming exercise are either negligible or absent, and instead, the immunological benefits gained through consistent swimming exercise outweigh any potential drawbacks.


Subject(s)
Asthma , Disinfectants , Swimming Pools , Swimming , Asthma/chemically induced , Disinfection/methods , Male , Mice , Animals , Humans , Water Pollutants, Chemical , Cytokines/metabolism
10.
Environ Sci Pollut Res Int ; 31(20): 30212-30227, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38602633

ABSTRACT

Photocatalytic disinfection is a promising technology with low cost and high efficiency. However, most of the current studies on photocatalytic disinfection ignore the widespread presence of natural organic matter (NOM) in water bodies, so the incomplete conclusions obtained may not be applicable. Herein, this paper systematically studied the influence of humic acid (HA), one of the most important components of NOM, on the photocatalytic inactivation of bacteriophage f2 with electrospinning Cu-TiO2 nanofibers. We found that with the addition of HA, the light transmittance of the solution at 550 nm decreased from 94 to 60%, and the band gap of the photocatalyst was increased from 2.96 to 3.05 eV. Compared with reacting without HA, the degradation amount of RNA of f2 decreased by 88.7% after HA was added, and the RNA concentration increased from 1.95 to 4.38 ng·µL-1 after the reaction. Hence, we propose mechanisms of the effect of HA on photocatalytic disinfection: photo-shielding, passivation of photocatalysts, quenching of free radicals, and virus protection. Photo-shielding and photocatalyst passivation lead to the decrease of photocatalyst activity, and the reactive oxygen species (ROSs) (·OH, ·O2-, 1O2, H2O2) are further trapped by HA. The HA in water also can protect the shape of phage f2 and reduce the leakage of protein and the destruction of ribonucleic acid (RNA). This work provides an insight into the mechanisms for the influence of HA in photocatalytic disinfection process and a theoretical basis for its practical application.


Subject(s)
Bacteriophages , Copper , Disinfection , Humic Substances , Nanofibers , Titanium , Titanium/chemistry , Titanium/pharmacology , Disinfection/methods , Copper/chemistry , Copper/pharmacology , Nanofibers/chemistry , Catalysis , Light
11.
Sci Total Environ ; 929: 172498, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38657805

ABSTRACT

The drugs and personal care products in water sources are potential threats to the ecological environment and drinking water quality. In recent years, the presence of PPCPs has been detected in multiple drinking water sources in China. PPCPs are usually stable and resistant to degradation in aquatic environments. During chlorination, chloramination, and ozonation disinfection processes, PPCPs can act as precursor substances to generate N-nitrosodimethylamine (NDMA) which is the most widely detected nitrosamine byproduct in drinking water. This review provides a comprehensive overview of the impact of PPCPs in China's water environment on the generation of NDMA during disinfection processes to better understand the correlation between PPCPs and NDMA generation. Chloramine is the most likely to form NDMA with different disinfection methods, so chloramine disinfection may be the main pathway for NDMA generation. Activated carbon adsorption and UV photolysis are widely used in the removal of NDMA and its precursor PPCPs, and biological treatment is found to be a low-cost and high removal rate method for controlling the generation of NDMA. However, there are still certain regional limitations in the investigation and research on PPCPs, and other nitrosamine by-products such as NMEA, NDEA and NDBA should also be studied to investigate the formation mechanism and removal methods.


Subject(s)
Dimethylnitrosamine , Disinfection , Water Pollutants, Chemical , Water Purification , China , Disinfection/methods , Water Purification/methods , Water Pollutants, Chemical/analysis , Dimethylnitrosamine/analysis , Drinking Water/chemistry , Disinfectants/analysis
12.
Oral Health Prev Dent ; 22: 151-158, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38652288

ABSTRACT

PURPOSE: To investigate the effect of full-mouth disinfection on the sizes of the periodontal wound and periodontal inflammatory burden and whether it leads to a decrease in C-reactive protein (CRP) levels. MATERIALS AND METHODS: The study included 20 systemically healthy subjects (11 women and 9 men) 30 to 68 years old with localised or generalised periodontitis (stage III, grade C). The sizes of the periodontal wound and periodontal inflammatory burden were measured with the web application "Periodontalwound", which is based on measurements of average tooth cervices, as well as probing depths and bleeding on probing assessed at six sites around each tooth present in the oral cavity. The levels of hsCRP (high-sensitivity CRP) were measured with an immunochemical method. All three parameters were measured before initial treatment and 3 months after therapy. Full-mouth disinfection included removal of plaque and calculus with ultrasonic and hand instruments in one session. RESULTS: The results showed a statistically significant decrease in the size of the periodontal wound (p < 0.001), a statistically significant decrease in the size of periodontal inflammatory burden (p < 0.001), and a decrease in hsCRP levels 3 months after therapy. CONCLUSION: Full-mouth disinfection leads to a decrease in the periodontal wound and periodontal inflammatory burden size, as well as a decrease in the levels of hsCRP in patients with localised or generalised periodontitis (stage III, grade C).


Subject(s)
C-Reactive Protein , Disinfection , Humans , Male , Female , C-Reactive Protein/analysis , Middle Aged , Adult , Aged , Disinfection/methods , Periodontitis , Periodontal Index , Dental Plaque , Dental Calculus , Periodontal Pocket , Ultrasonic Therapy/methods
13.
World J Urol ; 42(1): 252, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38652324

ABSTRACT

BACKGROUND: To prevent infectious complications after transrectal ultrasound-guided prostate biopsy (TRUS-PB), some studies have investigated the efficacy of rectal disinfection using povidone-iodine (PI) and antibiotic prophylaxis (AP). OBJECTIVE: To summarize available data and compare the efficacy of rectal disinfection using PI with non-PI methods prior to TRUS-PB. EVIDENCE ACQUISITION: Three databases were queried through November 2023 for randomized controlled trials (RCTs) analyzing patients who underwent TRUS-PB. We compared the effectiveness of rectal disinfection between PI groups and non-PI groups with or without AP. The primary outcomes of interest were the rates of overall infectious complications, fever, and sepsis. Subgroups analyses were conducted to assess the differential outcomes in patients using fluoroquinolone groups compared to those using other antibiotics groups. EVIDENCE SYNTHESIS: We included ten RCTs in the meta-analyses. The overall rates of infectious complications were significantly lower when rectal disinfection with PI was performed (RR 0.56, 95% CI 0.42-0.74, p < 0.001). Compared to AP monotherapy, the combination of AP and PI was associated with significantly lower risk of infectious complications (RR 0.54, 95% CI 0.40-0.73, p < 0.001) and fever (RR 0.47, 95% CI 0.30-0.75, p = 0.001), but not with sepsis (RR 0.49, 95% CI 0.23-1.04, p = 0.06). The use of fluoroquinolone antibiotics was associated with a lower risk of infectious complications and fever compared to non-FQ antibiotics. CONCLUSION: Rectal disinfection with PI significantly reduces the rates of infectious complications and fever in patients undergoing TRUS-PB. However, this approach does not show a significant impact on reducing the rate of sepsis following the procedure.


Subject(s)
Anti-Infective Agents, Local , Image-Guided Biopsy , Povidone-Iodine , Prostate , Rectum , Humans , Male , Anti-Infective Agents, Local/therapeutic use , Anti-Infective Agents, Local/administration & dosage , Antibiotic Prophylaxis/methods , Disinfection/methods , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Povidone-Iodine/therapeutic use , Povidone-Iodine/administration & dosage , Prostate/pathology , Prostatic Neoplasms/pathology
14.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38608912

ABSTRACT

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Subject(s)
Disinfection , Drinking Water , Water Purification , Drinking Water/microbiology , Drinking Water/chemistry , Disinfection/methods , Water Purification/methods , Water Microbiology , Water Supply
15.
Life Sci Space Res (Amst) ; 41: 56-63, 2024 May.
Article in English | MEDLINE | ID: mdl-38670653

ABSTRACT

The prevention and reduction of microbial species entering and leaving Earth's biosphere is a critical aspect of planetary protection research. While various decontamination methods exist and are currently utilized for planetary protection purposes, the use of far-UVC light (200-230 nm) as a means for microbial reduction remains underexplored. Unlike conventional germicidal ultraviolet at 254 nm, which can pose a health risk to humans even with small exposure doses, far-UVC light poses minimal health hazard making it a suitable candidate for implementation in occupied areas of spacecraft assembly facilities. This study investigates the efficacy of far-UVC 222-nm light to inactivate bacteria using microbial species which are relevant to planetary protection either in vegetative cell or spore form. All the tested vegetative cells demonstrated susceptibility to 222-nm exposure, although susceptibility varied among the tested species. Notably, Deinococcus radiodurans, a species highly tolerant to extreme environmental conditions, exhibited the most resistance to far-UVC exposure with a dose of 112 mJ/cm2 required for a 1-log reduction in survival. While spore susceptibility was similar across the species tested, Bacillus pumilus spores were the most resistant of the tested spores when analyzed with a bi-exponential cell killing model (D90 of 6.8 mJ/cm2). Overall, these results demonstrate the efficacy of far-UVC light for reducing microbial bioburden to help ensure the success and safety of future space exploration missions.


Subject(s)
Spacecraft , Spores, Bacterial , Ultraviolet Rays , Spores, Bacterial/radiation effects , Extremophiles/physiology , Extremophiles/radiation effects , Deinococcus/radiation effects , Deinococcus/physiology , Disinfection/methods
16.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622548

ABSTRACT

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Subject(s)
Disinfectants , Disinfection , Humans , Disinfection/methods , Glutaral , Sodium Hypochlorite , Dental Impression Materials , Dental Impression Technique
17.
PLoS One ; 19(4): e0302258, 2024.
Article in English | MEDLINE | ID: mdl-38626152

ABSTRACT

Effective surface disinfection is crucial for preventing the spread of pathogens in hospitals. Standard UltraViolet-C (UV-C) lamps have been widely used for this purpose, but their disinfection efficiency under real-world conditions is not well understood. To fill this gap, the influence of the power of the ultraviolet radiator, source-sample distance, and exposure time on the performance of UV-C lamps against Escherichia coli and Staphylococcus epidermidis were experimentally determined in the laboratory and hospital. The obtained results showed that the UV irradiance and, thus, the UV-C disinfection efficiency decreased significantly at distances greater than 100 cm from the UV-C lamp. Moreover, increasing the total power of the radiators does not improve the performance of UV-C lamps under real conditions. The UV-C disinfection efficiency greater than 90% was achieved only under laboratory conditions at a close distance from the UV-C lamp, i.e., 10 cm. These findings provide novel insights into the limitations of UV-C lamps in real-world conditions and highlight the need for more effective disinfection strategies in hospitals.


Subject(s)
Escherichia coli , Ultraviolet Rays , Disinfection/methods
18.
Food Microbiol ; 121: 104516, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38637078

ABSTRACT

Oxidation-reduction potential (ORP) is commonly used as a rapid measurement of the antimicrobial potential of free chlorine during industrial fresh produce washing. The current study tested the hypothesis that ORP can act as a "single variable" measurement of bacterial (vegetative and endospores) inactivation effectiveness with free chlorine irrespective of the water pH value. This situation has on occasion been assumed but never confirmed nor disproven. Chlorine-dosed pH 6.5 and 8.5 phosphate buffer solutions were inoculated with Escherichia coli (E. coli), Listeria innocua (L. innocua), or Bacillus subtilis (B. subtilis) endospores. ORP, free chlorine (FC), and log reduction were monitored after 5 s (for E. coli and L. innocua) and up to 30 min (for B. subtilis spores) of disinfection. Logistic and exponential models were developed to describe how bacteria reduction varied as a function of ORP at different pH levels. Validation tests were performed in phosphate buffered pH 6.5 and 8.5 cabbage wash water periodically dosed with FC, cabbage extract and a cocktail of Escherichia coli O157:H7 (E. coli O157:H7) and Listeria monocytogenes (L. monocytogenes). The built logistic and exponential models confirmed that at equal ORP values, the inactivation of the surrogate strains was not consistent across pH 6.5 and pH 8.5, with higher reductions at higher pH. This is the opposite of the well-known free chlorine-controlled bacterial inactivation, where the antibacterial effect is higher at lower pH. The validation test results indicated that in the cabbage wash water, the relationship between disinfection efficiency and ORP was consistent with the oxidant demand free systems. The study suggests that ORP cannot serve as a reliable single variable measurement to predict bacterial disinfection in buffered systems. When using ORP to monitor and control the antibacterial effectiveness of the chlorinated wash water, it is crucial to take into account (and control) the pH.


Subject(s)
Escherichia coli O157 , Listeria monocytogenes , Listeria , Disinfection/methods , Chlorine/pharmacology , Chlorine/analysis , Food Contamination/analysis , Food Microbiology , Oxidants , Colony Count, Microbial , Food Handling/methods , Chlorides , Oxidation-Reduction , Water/chemistry , Anti-Bacterial Agents , Hydrogen-Ion Concentration , Phosphates
19.
Food Microbiol ; 121: 104523, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38637085

ABSTRACT

This study investigated the fungicidal efficiency and mechanism of action of dielectric barrier discharge cold atmosphere plasma (DBD-CAP) in inactivating Aspergillus niger (A. niger) spores. The disinfection efficacy and quality of dried jujube used as the processing application object were also studied. The results indicated that the Weibull + Tail model performed better for spore inactivation curves at different voltages among various treatment times, and the spore cells were reduced by 4.05 log (cfu/mL) in spores suspension at 70 kV after 15 min of treatment. This disinfection impact was further supported by scanning electron microscope (SEM) and transmission electron microscopy (TEM) images, which showed that the integrity of the cell membrane was damaged, and the intracellular content leaked out after DBD-CAP treatment. Elevated levels of reactive oxygen species (ROS) during the treatment increased the relative conductivity of cells, and leakage of nucleic acids and proteins further supported the disinfection impact. Additionally, the growth and toxicity of surviving A. niger spores after treatment were also greatly reduced. When DBD-CAP was applied to disinfecting dried jujube, the spore number exhibited a 2.67 log cfu/g reduction after treatment without significant damage observed onto the quality (P > 0.05).


Subject(s)
Aspergillus , Plasma Gases , Ziziphus , Aspergillus niger , Plasma Gases/pharmacology , Disinfection/methods
20.
Environ Sci Technol ; 58(15): 6552-6563, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38571383

ABSTRACT

Extracellular polymeric substances (EPS) ubiquitously encapsulate microbes and play crucial roles in various environmental processes. However, understanding their complex interactions with dynamic bacterial behaviors, especially during the disinfection process, remains very limited. In this work, we investigated the impact of EPS on bacterial disinfection kinetics by developing a permanent EPS removal strategy. We genetically disrupted the synthesis of exopolysaccharides, the structural components of EPS, in Pseudomonas aeruginosa, a well-known EPS-producing opportunistic pathogen found in diverse environments, creating an EPS-deficient strain. This method ensured a lasting absence of EPS while maintaining bacterial integrity and viability, allowing for real-time in situ investigations of the roles of EPS in disinfection. Our findings indicate that removing EPS from bacteria substantially lowered their susceptibility threshold to disinfectants such as ozone, chloramine B, and free chlorine. This removal also substantially accelerated disinfection kinetics, shortened the resistance time, and increased disinfection efficiency, thereby enhancing the overall bactericidal effect. The absence of EPS was found to enhance bacterial motility and increase bacterial cell vulnerability to disinfectants, resulting in greater membrane damage and intensified reactive oxygen species (ROS) production upon exposure to disinfectants. These insights highlight the central role of EPS in bacterial defenses and offer promising implications for developing more effective disinfection strategies.


Subject(s)
Disinfectants , Disinfection , Disinfection/methods , Extracellular Polymeric Substance Matrix , Disinfectants/pharmacology , Chlorine/pharmacology , Kinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...